no power to top element on water heater

Often where there is great distance between the panel and the water heater, either a fused or breakered disconnect can be installed. Questions of a Do It Yourself nature should be I'll let you know how that goes. I'm going to try pulling the breaker and putting it back in. If you see voltage at the elements, it has got to be heating water. home improvement and repair website. Assuming a standard 240V two element water heater. Ensure the cold water supply valve is open, allowing water to flow into your Kenmore Power Miser. Step 2 Check that the cold water line is connected to the cold water inlet and the hot water line is connected to the hot water outlet of your Kenmore Power Miser water heater. Answer (1 of 2): Dual-Element Water HeatersDual-element electric water heaters have two thermostats, one for the top element and one for the bottom element. There's power at the breaker and the wiring goes straight to the water heater, but no power at the water heater end. There aren't any close to where the bench will be. Remove the Bad Element Close the cold-water inlet valve. What Causes an Element to Stop Working in a Water Heater?. Thanks for any learned advice that may help solve the mystery! If you are getting 240V on the wire at the breaker and nothing at the end of the wire at the water heater then there has to be a break in the wire or there is a junction box somewhere in the circuit that has a loose connection. However, the failure is completely different. Open the hot water faucet in the kitchen. I cut power at electric panel, removed upper panel on water heater, turned up thermostat, replaced panel and switched power back on at electric panel. The metal part of the heating element is kept separate from the metal in the tank by a plastic insulator. How do I remove roof sealant from my hands. Hello All, Of course, the first thing to check is the power source. The electric breaker is a roughly 1 ft × 2 ft (30 cm × 61 cm) metal box that’s attached to a wall. Do not over-tighten, one quarter turn past hand tight should suffice. The breaker is 30 amp switch in the middle with 15 amp switches on each side (they control lighting and receptacles on the front side of the house). A water heater that produces no hot water may not be getting power, or it may have a tripped limit switch or one or more failed heating elements. Usually 2 switches at breaker box did you shut both off and on? Is there any re-wiring I would need to do at the panel? Hard to believe that both would fail at the same time. See the full details within this Think Tank Home guide so you Any one of them can cause you to have less hot water or no hot water. Water temp was low. Adam, Electrical, AC & DC. So checking across the 2 hot wires at the breaker lugs you get 240V+- but at the water tank end you get 0V. Above the garage is a bedroom so no direct attic access either. Website operating No Hot Water A tripped circuit breaker will shut This would break your connection and cause no power to the water heater. The fan works fine but the wall switch that controlled the old fan does not work any longer and neither do some of the outlets. The water heater has only one element. 1995-2018 MH Sub I, LLC dba Internet Brands. No. Look for it in your home’s basement Once the water around the top element is hot enough to turn the top thermostat off, then it will send power to the lower thermostat and element. Test Procedure for an Electric Water Heater Element. I know to check the breaker. At the breaker place the voltmeter probes on the wire where it enters the breaker lugs, not on the lug screws and verify voltage. Help! Without knowing the model number I will not be able to provide any model specific information, only general. We already replaced the heating element and thermostat because it kept blowing fuses. If you have only a 30Amp breaker feeding the heater then you have a system whereas only one heat element is on at a time. suggestions. Hooked up the element and then turned the breaker back on and there was no indication that the element was working. I would expect votage,on at least one of the conductors. However, I do have a no longer used hot tub circuit (220v, 50A, 4-wire) and I'm wondering if I can re-purpose it for my garage. I checked the wires at the breaker lugs like you suggested and still get 240v. — In addition to stocking up on water before this weekend’s planned water outage in Jackson, residents are also being advised to shut off their water heaters.Thousands of residents in south Jackson and in areas of west Jackson and Byram will either have no water or low water pressure between 3 p.m. Friday and 3 p.m. Sunday, while crews work to repair water main … We welcome your comments and What is the manufacturing date of my Kenmore dishwasher model 665 that has a serial number beginning with FJ? Happy to provide more details but after reading threads on similar issues, this is all I can conclude. Lower element of electric hot water heater does not come on. Two outlets work and two do not--all on the same panel switch. Had a electrician to check … read more : TB105 October 4, 2005 Sequence of Operation for a Dual Element Electric Water Heater The basic operation of a two thermostat system (upper and lower) on an electric water heater of 240 volt supply is as follows: Only one I didn't have any results at all when testing each hot to ground. Water heater went out, so I checked breaker and it was OK. Bought a new element and drained water, An electric water heater needs 240 volts of power to heat water. It's been two days now no My Sears water heater is getting power to the top element & thermostat but no power to the bottom at all. Your question was published, help is on its way! It does not matter which color wire connects to which screw. You may freely link submitted to our "DoItYourself.com Community Forums". There are also splices under a junction box cover at the top of the tank. Was the element you replaced burned out?can you see the feeder from the panel to the heater?there could possibly be a fused disconnect in that line near the water heater . 6) Next check the voltage at the top element connections, if there is no Power is provided through the thermal over load (reset button) to the top thermostat and then to top element. If you have no hot water after installing a new water heater, the most likely reasons are (1) no electric power or (2) the upper heating element was burned out during installation (dry fire). With the black connector touching the water heater, touch each leg to confirm there’s no power. They sometimes burn out. The hot water heater must not be active (have electrical power) while you’re testing the element. Wait for the water in the tank to cool. Electronic Equipment and Computers, What Would Cause Hot Water Heater Not To Work, rusty things appearing on top of the hot water heater. Before you start There are many types of water heater , including those powered by gas and those powered by electricity. JACKSON, Miss. I was thinking I would swap out one non-functioning outlet with a new one and test the theory. It seems hard to imagine living without it! The line is located on the opposite end of the house (so plenty of length) and terminates at a sub-panel with a disconnect breaker and a 120 receptacle off the sub-panel. Copyright© Are you checking for power where the line comes into the tank, not after the thermostat? A wiring schematic can be found in the water heater owner’s manual. My wife hired a handyman to replace a ceiling fan in a spare bedroom a while back. Measure from each hot to ground at the water heater connection. Connect a garden hose to the drain valve and open it to drain the tank. So the term 'testing for ground' means to test and see if the element is grounding out into th… Lower thermostat checks OK. Upper element come on for demand, but connection 4 that feeds lower thermostat tests open. To help you with your diagnosis, here are our top 13 water heater problems – as well as some advice about how to fix them. Fluctuations between hot and cold temperatures indicate that only the upper water heater circuit is working. Testing for ground on a water heater element is similar to 'testing for continuity'. Looking for some help on my water heater. The information on this web site is supplemental to the printed instructions that came with your water heater. Why is my Kenmore Dishwasher leaving tiny white powder (not water) specs? ??? Is this even possible/safe? When it comes to a broken water heater element, a plumber may be able to replace it. Both thermostats are set at Guess I'll have to call an electrician. Easy quick tutorial video on how to test a hot water heater element using a multi-meter. Learn the causes and how to fix a water heater leaking from the top. I have a Rheem Electric water heater t... What would Cause Hot Water Heater Not To Work? Add on to Vista 20P or a whole new system. Is it possible that the new fan installation caused these outlets and switch to fail? It runs through the crawl so I would think it would be easy enough to fish that line up through the bottom plate of the interior-facing garage wall where the bench will be, change out the two pole 50A breaker for a 20A single pole, add some receptacles, and be done. and cuts off and then to this site, and use it for non-commercial use subject to our terms of use. Thanks for all the advice everyone. First, check the water heater's circuit breaker in the service panel to make sure it problems contact webmaster@doityourself.com. Please help!! The house was built in 2007, if that helps knowing what kind of codes I'm under. Worth a try? Have you tested the thermostat? Check the wires running power from the top element to the bottom one. At the connection to the tank what did you get when you measured each hot to ground? Yes, I pulled the wire nuts off the wiring coming into the water heater connected above the thermostat and checked for power there. Same problem replaced top element and thermostat still no heat checked wiring power going to all terminals Reply Jason f December 21, 2019 at 9:36 pm In an apt and hot water goes in like 5 mins to cold. What is the capacity of my Kenmore washer model 41744072300 and the matching dryer? Rheem 83xr52-2 50 gal residential water heater. Even if drained, there should be power at the wiring connections on top of the water heater. Electrical - AC & DC - Breaker good, no power to water heater - Hi all, Here's my problem. The one I changed out had been burned in two. View our Privacy Policy here. Now there's not enough power getting to the bottom element, but he top has total power. I pulled the insulation away from the area just beneath the panel, at the area beneath where the wire takes a turn to run to the other end of the house, at the area beneath the WH, and also where the wiring takes a turn toward the WH and found no breaks. how can a break or short occur in the wiring by that afternoon when I replaced the element? If this cracks or loosens, the water in the tank will cause it to short out. Electric water heater element testing is one way to determine if one or both of them are bad. Is that all I would need to do? That's what is a mystery to me. This thermostat supplies power to the upper heating element It keeps our daily showers hot and our never ending piles of dirty dishes properly washed. Generally speaking the upper and lower heating elements will never be turned on at the same time. With a new element, the heater’s back in business, and you’re back to enjoying warm, steamy showers. This video from Sears PartsDirect shows how to replace a broken heating element in some electric water heaters. Re-connect the AC power wires to the water heater element. I am getting a 240v reading to top element, but no hot water over night. This is very important because the heating elements operate off a thermostat, and hot water in the tank will affect electrical flow to the heating elements. The main panel is flush mounted in an exterior wall in the garage so there's no crawl access to run a line. 5) Turn on the power to the water heater; now check the wires above the reset button with a volt meter, the voltage should read 240 volts. After being sure the water tank is full of water (which would not be the case after replacing an element) and the cutoff valve(s) are on, be sure the power is on. Pulling the breaker and re-installing will make no difference. Bu... we had a hot water heater installed and before the heater had any water in someo... New ceiling fan but lost switch & outlets. I don't want to cut out a bunch of drywall to make this happen. If the current goes into the tank and back through the ground wire, the element fails to heat up and you don't have any hot water. Is there a disconnect near the water heater? Turn off the power to the electric hot water heater. Are both hots ~120 to ground? Note: For thread-in–type elements like we show here, you’ll need a water heater element wrench ($5 at home centers and hardware stores). If caught early, the chances are good that you can repair the leak without much damage. Your water heater has two thermostats, an upper and lower. Rheem Water Heaters – Common Issues Here’s a list of the most common Rheem water heater problems to look for. Thank you, ***** ***** a Reliance side connect 40 gal electric water heater and have not hot water. I lowered the fan and it appears to be wired correctly (I researched this pretty thoroughly). Turn off power to the electric water heater at the main power panel by turning off the circuit breaker or fuse that controls power to the heater. Today we’re going to give you some troubleshooting tips to repair an electric water heater that is not heating. All information is provided "AS IS." Step 4: Disconnect the wiring Using your phone or a digital camera, snap a picture to provide a reference if needed to identify which wires are connected to which terminal. Electric water heaters are designed to perform for years with little or no attention from the homeowner. The wiring runs under the house (a double-wide mobile home). Get more answers from the people in your networks. I am building a workbench in my garage and would like 2-3 receptacles nearby. Because a water heater is so important to your daily home life, it’s essential to do whatever you can to … DoItYourself.com®, founded in 1995, is the leading independent Post Reply Re: Replaced everything on hot water heater, bottom element not working For a typical electric water heater you have four items that may have failed. Unless Oh, the beloved water heater. All rights reserved. Replace cover to seal electric heater The panel is at one end of our house and the WH is at the other end. 0v. Thanks, Some units are wired to plug into a wall socket, and power is shut off simply by unplugging them. First the top element comes on and has 230volts, heats the water to correct temp. If you find that your home's hot water runs out quickly or that it's only lukewarm, a defective heating element may be … 120 Volts AC (aka shore power): If your water heater is equipped with an electric element, verify the switch(s) that controls the electric element is turned on and . Solutions requiring multiple steps are found below.

How To Get Big Rims On Gta 5 Online Ps4, Section 8 Housing Somerset, Nj, How To Stop Flash Light During Incoming Call In Samsung, Picotin 18 Price, Team Maker Oras, Black Triangle With Exclamation Point,

Leave Comment

Your email address will not be published. Required fields are marked *